I searched far and wide for the answer to this but came up empty handed, so here goes. I have a 1/4 NPT pressure gauge for my pneumatic cannon. I read once that the gauge should be installed through 2layers of overlapping PVC pipe, example of this is through the endcap. Is this necessary or can i just drill a hole and install into the chamber. I just want to do this right the first time
User avatar
Pilgrimman
Specialist 4
Specialist 4
Posts: 480
Joined: Thu Jun 28, 2007 1:10 pm
Location: Grants Pass, OR

What I do is buy a bushing that reduces to 1/2", put it on the chamber, then buy a brass bushing that goes from 1/2" to 1/4".
Yeah, we wouldn't want to anger the bees, now would we??

I HATE YOU BEES! I HATE YOU BEES! I HATE YOU BEES!

LMAO Classic!!!! I love Family Guy!
User avatar
rna_duelers
Staff Sergeant 3
Staff Sergeant 3
Posts: 1739
Joined: Mon Sep 26, 2005 7:07 am
Location: G-land Australia

What seems like a better thing to do?Have the hole drilled through two layers of PVC or one?Two layers is the logical choice for safety reasons. :wink:
Image
User avatar
BigGrib
Corporal 2
Corporal 2
Posts: 652
Joined: Mon Oct 01, 2007 11:43 pm
Location: TriCities, WA
Contact:

Simple answer to your question yes install it in a douple layer. More explained answer For a 1/4 NPT fitting drill a half inch hole and then thread the fitting pvc using the fitting to cut the threads in the pvc. once you have it screwed into the pvc take it back out and apply epoxy in and around the hole you just drilled and tapped and reinsert the fitting back into the pvc. Let the epoxy set and the install the guage into that fitting using lots of thread tape to seal it all up.
Yea, that's definitely going to get you at least a tazer.
<a href="">DONT TAZE ME BRO.. DONT TAZE ME... AHHHH</a>
facebook.com/biggrib
User avatar
Ragnarok
Captain
Captain
Posts: 5401
Joined: Tue Dec 19, 2006 8:23 am
Location: The UK

As I've said elsewhere, a perfectly round hole in a flat plate will reduce it's failure load by a factor of 3.
A threaded hole in a chamber wall has even worse stress concentration, of the order of 4 times weaker than the unmodified chamber wall.

Tapping through a double layer helps to counter this loss of strength - the double strength of the wall means the hole is around half the strength of the regular wall. Still not great, but a lot better than a quarter of the strength.
Does that thing kinda look like a big cat to you?
User avatar
limbeh
Specialist
Specialist
Posts: 128
Joined: Sun Dec 30, 2007 10:52 pm

Hey,

I'm thinking of doing this in 4" JIS AW PVC, which has a pressure rating of 10 bars (150 psi). My planned operating pressure is 110psi (120 max), would it still be safe to try installing a pressure gauge (same goes for a schrader / pilot valve) into a double layer of PVC (fitting + pipe)?

What if we get a female thread to socket adapter, drill an appropriately sized hole in the double layed of PVC, stick the adapter in (and solvent weld it), then thread the gauge in? Would it be any stronger than drilling a hole and using the gauge itself to thread through the hole?

Thanks.
User avatar
BigGrib
Corporal 2
Corporal 2
Posts: 652
Joined: Mon Oct 01, 2007 11:43 pm
Location: TriCities, WA
Contact:

yeah your fine with installing a gauge on that. i get my 1/4 npt male fittings to 1/8 npt female which i screw the gauge into and merely screw the fitting into the drilled hole see my how to above. but dont try to solvent weld a brass fitting into plastic cause that's useless. get some 5 minute set epoxy for like 5 bucks and mix a little up and epoxy the hole so that the epoxy will cover the threads as the fitting goes in. it's gonna make it so if something happens like you drop your gun and the gauge breaks you just unscrew the gauge from the fitting and replace it.
Yea, that's definitely going to get you at least a tazer.
<a href="">DONT TAZE ME BRO.. DONT TAZE ME... AHHHH</a>
facebook.com/biggrib
User avatar
jimmy101
Sergeant Major 2
Sergeant Major 2
United States of America
Posts: 3210
Joined: Wed Mar 28, 2007 9:48 am
Location: Greenwood, Indiana
Has thanked: 6 times
Been thanked: 18 times
Contact:

If you really want to install a gauge in the chamber, and not a fitting, you can double up the chamber wall where you install the fitting.

Take a hunk of pipe the same diameter as the chamber that is perhaps 2" long. Cut the piece of pipe in half (or so) lengthwise. Boil the c-shaped piece of pipe in water to soften it, press it against the chamber and hold until cool. If the piece springs back too much when removed from the chamber then repeat the process.

Thouroughly dry everything. Prime/clean and glue the piece onto the chamber. Clamp at least overnight for the glue to dry.

Drill and tap your hole through the double layer.
Image
User avatar
BigGrib
Corporal 2
Corporal 2
Posts: 652
Joined: Mon Oct 01, 2007 11:43 pm
Location: TriCities, WA
Contact:

man, that's a lot of pain in the ass. i tend to stick with an easy method that does what it needs to
Yea, that's definitely going to get you at least a tazer.
<a href="">DONT TAZE ME BRO.. DONT TAZE ME... AHHHH</a>
facebook.com/biggrib
xboxteen01
Private 3
Private 3
Posts: 55
Joined: Sat Oct 13, 2007 5:39 pm

alright thanks for the help guys
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post