Fuel Meter Volume To Combustion Chamber Volume?

Harnessing precision mixtures of pressurized flammable vapor. Not for the beginner.
spudkilla224
Private 4
Private 4
Posts: 65
Joined: Wed Mar 19, 2008 8:04 pm

Hello everyone, I am new to the hybrid side of potato cannons. And I have searched all over spudfiles, the spudtech archive and google and the wiki, and have not found anything that would tell me how I would calculate the fuel meter size to the combustion chamber size of a hyrbid cannon? :?

Any help would be appreciated!
User avatar
ramses
Staff Sergeant 2
Staff Sergeant 2
United States of America
Posts: 1679
Joined: Thu May 29, 2008 6:50 pm

Just like a normal combustion, except you would multiply the pressure or volume of the meter by the mix number you want. For example, if you want an 8x hybrid, you would multiply by 8. Hope that helped!
POLAND_SPUD wrote:even if there was no link I'd know it's a bot because of female name :D
spudkilla224
Private 4
Private 4
Posts: 65
Joined: Wed Mar 19, 2008 8:04 pm

Oh ic! I thought about that but I didn't think I was correct. so basically i should design the meter for the Highest mix i want to shoot at?
User avatar
kjjohn
Specialist 2
Specialist 2
Posts: 270
Joined: Sat Jul 11, 2009 3:54 pm
Contact:

Download HGDT, enter in the specs of your cannon, and then go to the load/mix calculator in the tools menu.
User avatar
ramses
Staff Sergeant 2
Staff Sergeant 2
United States of America
Posts: 1679
Joined: Thu May 29, 2008 6:50 pm

It would be a good idea to design the meter to work at around the max propane pressure for the highest mix you want. That way, you can turn down the pressure and get a lower mix with the same meter tube. The propane pressure you use should be dictated by the lowest operating temperature you can foresee.

Image

If that pressure is easily by the mix number, you make life easier on yourself. Ex. at 100psi, it will give you enough fuel for a 10x mix. That way, 6x=60psi, 7x=70psi, etc.

Hybrid meters can be more touchy than normal combustion meters, so it would be a good idea to measure the chamber volume with water or oil, and do the same for the meter.

obviously, don't make your hybrid out of PVC. A PVC meter should work okay though.
POLAND_SPUD wrote:even if there was no link I'd know it's a bot because of female name :D
spudkilla224
Private 4
Private 4
Posts: 65
Joined: Wed Mar 19, 2008 8:04 pm

Ok thanks for all of the info and help everyone! :idea:
Post Reply

Create an account or sign in to join the discussion