When your building a regular combustion spud gun, what raitio should you use between the area of the chamber and the barrel.
~JDSpud
Chamber To Barrel Ratio
- Pete Zaria
- Corporal 5

- Posts: 954
- Joined: Fri Mar 31, 2006 6:04 pm
- Location: Near Seattle, WA
It depends on the fuel.
As Garrattee said, you should search the forums and read the wiki. There's lots of info on this.
It's rumored (or should I say, agreed upon) that between 1:1 and 1.5:1 is best for hairspray and aerosol combustions, while .8:1 - 1:1 is best for metered propane. Keep in mind, if your chamber is too big you don't loose power - you just make more noise. For this reason I always tend to go a little chamber-heavy...
Peace,
Pete Zaria.
As Garrattee said, you should search the forums and read the wiki. There's lots of info on this.
It's rumored (or should I say, agreed upon) that between 1:1 and 1.5:1 is best for hairspray and aerosol combustions, while .8:1 - 1:1 is best for metered propane. Keep in mind, if your chamber is too big you don't loose power - you just make more noise. For this reason I always tend to go a little chamber-heavy...
Peace,
Pete Zaria.
Lighten up guys. He didn't ask how many people would like to tell me to go f*ck myself.JDSpud wrote:When your building a regular combustion spud gun, what raitio should you use between the area of the chamber and the barrel.
~JDSpud
Here's some research
http://www.burntlatke.com/launch.html
Try this online calculator
http://www.burntlatke.com/ratcalc.html
I agree that he should have searched too but they weren't being too mean. 1.5:1 (even for metered propane Pete
) is a powerful ratio .8:1 is very efficient. The "best" fuel mix is 4.3 (don't ask why its such an odd number, it's
from Burnt Latke and he does bunches of tests to prove his data).
from Burnt Latke and he does bunches of tests to prove his data).
- boilingleadbath
- Staff Sergeant 2

- Posts: 1635
- Joined: Sat Mar 12, 2005 10:35 pm
- Location: Pennsylvania, USA
JDSpud, you probably meant volume, in which case all of the above responses are correct.
However, if you acctualy meant <b>area</b>, it's another beast - and the response is "as big of a chamber diameter as is practical".
However, if you acctualy meant <b>area</b>, it's another beast - and the response is "as big of a chamber diameter as is practical".
Create an account or sign in to join the discussion
You need to be a member in order to post a reply
Create an account
Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute
Sign in
-
- Similar Topics
- Replies
- Views
- Last post
-
- 1 Replies
- 818 Views
-
Last post by jackssmirkingrevenge
-
- 3 Replies
- 2618 Views
-
Last post by Scotty
-
- 1 Replies
- 1327 Views
-
Last post by MrCrowley
-
- 0 Replies
- 3626 Views
-
Last post by PhoenixFire
-
- 2 Replies
- 897 Views
-
Last post by Technician1002