12 gram CO2 cartridge

From SpudFiles Wiki
Revision as of 16:39, 19 October 2005 by Boilingleadbath (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

CO2 cartriges are used primarily as a portable pressure scource. They are typicaly connected via an adapter. After being emptied, they are often shot at stuff - they have a nice mass, and are quite sturdy.


Here is a chart:

To calculate the pressure for any non-given valve, use this equation. (note that the pressure can't go above 800 psi, because that's CO2's vapor pressure) 4200/Chamber Volume In ci=Chamber Pressure -OR- 4200/CV=CP For example: You have a chamber volume of 41.3ci. So it can be said that 4200/41.3=CP 4200/41.3 is equal to 101.6949152542373 For simplicity's sake we will round this to 101.7 This means that CP=101.7psi You're 41.3ci chamber will have a pressure of 101.7psi when filled with one 12g CO2 tank. Simple, eh?

Chamber Size (ci)Chamber Pressure (psi)
10420
20210
30140
40105
5084
6070
7060
8053
9047
10042