looks like dwv?

Because potatoes only last one shot!
iknowmy3tables
Staff Sergeant
Staff Sergeant
United States of America
Posts: 1596
Joined: Fri Dec 15, 2006 3:57 pm
Location: maryland
Has thanked: 3 times
Been thanked: 9 times

I need to order a sch40 4" tee for my gun's valve but this mcmasters part looks an awful lot like a dwv fitting, I know mcmaster messes up the pics from time to time but they also don't separate always dwv from sch40 in fact they often consider dwv as sch40
http://www.mcmaster.com/itm/find.ASP?tab=find&context=psrchDtlLink&fasttrack=False&searchstring=4880K48
Image
User avatar
noob of noobs
Specialist 3
Specialist 3
Posts: 320
Joined: Tue Jun 12, 2007 8:04 pm
Location: Illinois, Skokie

I think it looks like DWV. The sockets lok way too shallow for nsf, but I could be wrong.
User avatar
bigbob12345
Staff Sergeant
Staff Sergeant
Posts: 1516
Joined: Sat Dec 01, 2007 9:13 am
Location: Mercer Island,Washington

That could not possibly be nsf as noob of noobs said the sockets are too short and it also just has DWV look to it
PVC Arsenal 17
Staff Sergeant 3
Staff Sergeant 3
Posts: 1762
Joined: Mon Mar 27, 2006 4:18 pm
Location: United States

I ordered a 4" tee from McMaster and it was a LASCO pressure rated fitting. I was, however, disappointed in the knit lines.
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

Those pictures are deceiving. Even on their pressure rated fittings, the display picture shows up as a DWV fitting sometimes.

If it's schedule 40, look for ASTM D2466, and the NSF rating is usually "NSF-61". Go by what you read, not what you see.
User avatar
pizlo
Corporal 3
Corporal 3
Posts: 783
Joined: Fri Dec 22, 2006 7:27 pm
Contact:

As mark said the pictures are NOT what you should base your assumptions on, If they say its pressure rated it is. But better safe then sorry, if it looks unstable you could contact mcmaster.
User avatar
DYI
First Sergeant 5
First Sergeant 5
Antigua & Barbuda
Posts: 2862
Joined: Sat Jul 07, 2007 8:18 pm
Location: Here and there

DWV usually is SCH40, its the pressure rating you're looking for. Mark's advice is correct. Look for NSF-61 or NSF-PW on PVC fittings, because logic would tell us that all potable water systems must use pressure for delivery, and therefore must be pressure rated. This line of thinking also explains why DWV can be pressure rated.
Spudfiles' resident expert on all things that sail through the air at improbable speeds, trailing an incandescent wake of ionized air, dissociated polymers and metal oxides.
User avatar
BigGrib
Corporal 2
Corporal 2
Posts: 652
Joined: Mon Oct 01, 2007 11:43 pm
Location: TriCities, WA
Contact:

And looking at the picture, even though it looks like a dwv fitting remember that it's a 4" fitting and the scale might be a bit off, but once again you can't always judge by the picture.
Yea, that's definitely going to get you at least a tazer.
<a href="">DONT TAZE ME BRO.. DONT TAZE ME... AHHHH</a>
facebook.com/biggrib
iknowmy3tables
Staff Sergeant
Staff Sergeant
United States of America
Posts: 1596
Joined: Fri Dec 15, 2006 3:57 pm
Location: maryland
Has thanked: 3 times
Been thanked: 9 times

ok, arsenal what do you mean by kit lines do you mean that it doesn't come in standard shape
clide
Corporal 3
Corporal 3
Posts: 784
Joined: Sun Mar 06, 2005 3:06 am
Location: Oklahoma, USA
Been thanked: 1 time

Knit lines are very thin lines formed from multiple flows of plastic joining up again after flowing around the mold. They look like hairline cracks and usually aren't seen unless you are really looking for them.

Take a fitting and look very closely at the side opposite of the nub left from where the PVC was injected and you'll be able to see a faint line. It's probably easier to see on larger fittings.
<a href="http://gbcannon.com" target="_blank"><img src="http://gbcannon.com/pics/misc/pixel.png" border="0"></a>latest update - debut of the cardapult
User avatar
frankrede
Sergeant Major 2
Sergeant Major 2
Posts: 3220
Joined: Thu Jul 20, 2006 9:47 pm
Has thanked: 1 time
Been thanked: 1 time

clide wrote:Knit lines are very thin lines formed from multiple flows of plastic joining up again after flowing around the mold. They look like hairline cracks and usually aren't seen unless you are really looking for them.

Take a fitting and look very closely at the side opposite of the nub left from where the PVC was injected and you'll be able to see a faint line. It's probably easier to see on larger fittings.
I see it on my 4" sch 80 fittings:( do they compromise the strength in that area?
Current project: Afghanistan deployment
clide
Corporal 3
Corporal 3
Posts: 784
Joined: Sun Mar 06, 2005 3:06 am
Location: Oklahoma, USA
Been thanked: 1 time

frankrede wrote:I see it on my 4" sch 80 fittings:( do they compromise the strength in that area?
I don't think the strength is compromised, if it is then it is surely accounted for in the design since any fitting that has two flows converge will have them. The only fittings I can think of that wouldn't have them is caps and plugs
<a href="http://gbcannon.com" target="_blank"><img src="http://gbcannon.com/pics/misc/pixel.png" border="0"></a>latest update - debut of the cardapult
User avatar
SpudMonster
Specialist 2
Specialist 2
Posts: 250
Joined: Mon Aug 08, 2005 5:54 pm

For what it's worth, lasco fittings are just about the worst fittings you can buy. They will work fine for spudgun applications, but if you can find Spears or Duro fittings, they are WAY better.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in