fueling biohazard

Harnessing precision mixtures of pressurized flammable vapor. Not for the beginner.
User avatar
pat123
Corporal
Corporal
Posts: 514
Joined: Sat Dec 23, 2006 10:08 pm
Location: S.C.
Contact:

last week when drex came over we couldn't get biohazard to shoot. just by roughly measuring the size i got the amount of propane needed to be 45psi. by filling it with water to measure it I got 40psi. we tried it at both and it wouldn't work. :x

after that we started at 60 psi of propane in the meter and tried to fire it. when that didn't work we went down 5 psi and it still didn't work. we continued to go down 5 psi at a time until we got to 5psi. then we just let it all out and pushed the button and it fired. why would it fire with all most no propane in it but it wouldn't when the "right amount" was in it? :?:

are we just missing something obvious?
User avatar
DYI
First Sergeant 5
First Sergeant 5
Antigua & Barbuda
Posts: 2862
Joined: Sat Jul 07, 2007 8:18 pm
Location: Here and there

Unless you post the calculations you did to find your meter pressure, we can't help.

If you do that, there's a good chance I'll be able to find your problem, although I don't have any hands-on experience with volumetric fuel meters.
Spudfiles' resident expert on all things that sail through the air at improbable speeds, trailing an incandescent wake of ionized air, dissociated polymers and metal oxides.
User avatar
STHORNE
Sergeant 3
Sergeant 3
Posts: 1208
Joined: Wed Feb 14, 2007 7:50 pm
Location: Kewaunee, Wisconsin

There could also be an ignition problem. Have you checked that out?
Forum Rules - follow them or else!
“Happiness is the meaning and the purpose of life, the whole aim and end of human existence”
User avatar
psycix
Sergeant Major 4
Sergeant Major 4
Posts: 3684
Joined: Mon Jun 25, 2007 7:12 am
Location: The Netherlands

Was there still air in your fuel meter when you tried it at the "right" amount of fuel?
Did you vent it properly before fireing off the "way too low" amount of fuel?

Those are my first thoughts of what happened to you.
Till the day I'm dieing, I'll keep them spuddies flying, 'cause I can!

Spudfiles steam group, join!
User avatar
pat123
Corporal
Corporal
Posts: 514
Joined: Sat Dec 23, 2006 10:08 pm
Location: S.C.
Contact:

I am going to measure it again with water to get a more accurate measure but it is about 620in3. I used the program i made http://www.spudfiles.com/forums/hcmp-t13837.html which i am pretty sure is accurate. the meter is 9.4 cubic inches.

I don't think the problem is in the calculations. i think i measured one of them wrong. but since we tried it at 5 psi intervals starting at 0 going to 60 i think something else maybe wrong.
User avatar
pat123
Corporal
Corporal
Posts: 514
Joined: Sat Dec 23, 2006 10:08 pm
Location: S.C.
Contact:

There could also be an ignition problem. Have you checked that out?
I hear it sparking every time
Was there still air in your fuel meter when you tried it at the "right" amount of fuel?
Did you vent it properly before fireing off the "way too low" amount of fuel?
Those are my first thoughts of what happened to you.
we pumped it out with a vacuum pump

edit: Sorry for the double post but they are both different and i didn't read the other two messages before i posted this one.
User avatar
DYI
First Sergeant 5
First Sergeant 5
Antigua & Barbuda
Posts: 2862
Joined: Sat Jul 07, 2007 8:18 pm
Location: Here and there

Okay, for this design, the volume of propane needed to fire at 1x is:
[(620ci/95.98 )*100-620]
26ci. (actually 25.9691ci, but we wouldn't want SB15 to be offended :wink: ).

Now, your meter will likely be full of air on the first shot, so on the first shot you would need to fill it to:
{[(26+9.4)/9.4]*14.7}
55psia or 40.7psig.
On the second shot, if the meter is full of propane, you would need:
[(26/9.4)*14.7]
41psia or 26psig.

Remember, this is all for 1x.

At 2x, you would need:
{[(620*2)/95.98]*100-620}
52ci of propane, requiring a meter pressure of 81psig if the meter was full of air or combustion products to start with, or 67psig if the meter was purged with propane beforehand.

Note that these numbers don't take into account the miniscule effect of the air or combustion products that might be in the meter if it wasn't purged.

Judging by these numbers, you couldn't usually exceed 3x without having to dump the meter twice, which complicates things even further. Ever thought of using a chamber pressure meter instead?
Spudfiles' resident expert on all things that sail through the air at improbable speeds, trailing an incandescent wake of ionized air, dissociated polymers and metal oxides.
User avatar
pat123
Corporal
Corporal
Posts: 514
Joined: Sat Dec 23, 2006 10:08 pm
Location: S.C.
Contact:

Ever thought of using a chamber pressure meter instead?
we are thinking about it but we already have the meter. we probably will. We could use the meter for part of a pnuematic or something.
User avatar
drex
Specialist
Specialist
Posts: 139
Joined: Mon Apr 21, 2008 4:00 pm

i want to use one of DYI's fancy chamber pressure meter instead, but im broke and pats to cheap. :roll: .

pat, lets see if we can't come up with the money and order the parts this weekend?
User avatar
SpudFarm
First Sergeant 3
First Sergeant 3
Posts: 2571
Joined: Sat Nov 04, 2006 9:39 am
Location: Norway Trondheim area

DYI i have decided.. i think i use your meter on my hybrid. seems like big hybrids are hard to fuel. (should be easier to fuel big chambers :? )

i talk to you on MSN about it so i don't hijack this
"Made in France"
- A spud gun insurance.
User avatar
pat123
Corporal
Corporal
Posts: 514
Joined: Sat Dec 23, 2006 10:08 pm
Location: S.C.
Contact:

i talk to you on MSN about it so i don't hijack this
go ahead and talk about it here i would like to know as much about it as you
User avatar
SpudUke5
Sergeant
Sergeant
Posts: 1099
Joined: Tue Sep 04, 2007 10:16 pm

DYI wrote:Okay, for this design, the volume of propane needed to fire at 1x is:
[(620ci/95.98 )*100-620]
26ci. (actually 25.9691ci, but we wouldn't want SB15 to be offended :wink: ).

Now, your meter will likely be full of air on the first shot, so on the first shot you would need to fill it to:
{[(26+9.4)/9.4]*14.7}
55psia or 40.7psig.
On the second shot, if the meter is full of propane, you would need:
[(26/9.4)*14.7]
41psia or 26psig.

Remember, this is all for 1x.


At 2x, you would need:
{[(620*2)/95.98]*100-620}
52ci of propane, requiring a meter pressure of 81psig if the meter was full of air or combustion products to start with, or 67psig if the meter was purged with propane beforehand.

Note that these numbers don't take into account the minuscule effect of the air or combustion products that might be in the meter if it wasn't purged.

Judging by these numbers, you couldn't usually exceed 3x without having to dump the meter twice, which complicates things even further. Ever thought of using a chamber pressure meter instead?
Why do you use 95.98? Shouldnt it be 95.8?
4SPC, My 4" piston 3" porting cannon
Memo:
Fix up copper cannon
Fix up 4SPC
Start Stirrup pump
Start Toolies piston bazooka
User avatar
SpudFarm
First Sergeant 3
First Sergeant 3
Posts: 2571
Joined: Sat Nov 04, 2006 9:39 am
Location: Norway Trondheim area

pat123 wrote:
i talk to you on MSN about it so i don't hijack this
go ahead and talk about it here i would like to know as much about it as you
nah it would just go off topic. you can PM me if you want to know.
thanks anyway :)
"Made in France"
- A spud gun insurance.
User avatar
DYI
First Sergeant 5
First Sergeant 5
Antigua & Barbuda
Posts: 2862
Joined: Sat Jul 07, 2007 8:18 pm
Location: Here and there

Why do you use 95.98? Shouldnt it be 95.8?
It's a number that others have quoted. I actually get 95.6 when I do the numbers myself. Ask Rag, as I'm sure he'll have the explanation behind the 95.98 number. Regardless of what the correct numbers are, the basis of the equation stays the same, and the results will be very close.
Spudfiles' resident expert on all things that sail through the air at improbable speeds, trailing an incandescent wake of ionized air, dissociated polymers and metal oxides.
User avatar
SpudUke5
Sergeant
Sergeant
Posts: 1099
Joined: Tue Sep 04, 2007 10:16 pm

Ok thanks i was just wondering mif you got that of the hybrid fueling sticky but i couldnt seem to find it.

So pat, have your tried what we have told you?
4SPC, My 4" piston 3" porting cannon
Memo:
Fix up copper cannon
Fix up 4SPC
Start Stirrup pump
Start Toolies piston bazooka
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post
  • ?s with biohazard.
    by pat123 » » in Hybrid Cannons
    36 Replies
    7797 Views
    Last post by drex
  • Biohazard Build Log
    by pat123 » » in Hybrid Cannons
    29 Replies
    5975 Views
    Last post by SpudFarm
  • Fueling
    by Juggernaut12121 » » in Hybrid Cannons
    8 Replies
    5003 Views
    Last post by Juggernaut12121
  • Fueling
    by maniacrobbins » » in General Cannon Discussion
    4 Replies
    2011 Views
    Last post by sgort87
  • hybrid fueling
    by jakethebeast » » in Hybrid Cannons
    24 Replies
    8422 Views
    Last post by jakethebeast