Does the shape of the adaper(110 to 50)makes any difference

A place for general potato gun questions and discussion.
Taavet
Private
Private
Posts: 11
Joined: Thu Jun 05, 2008 2:46 pm

Hey , im a spud-rookie...


Need your Pro-spud advice!

I got an adapter, little different from the ''standard'' (used by most of the spud-masters) thing... mine adapters nozzle isn't in the middle, it's ''drifted'' to one side :oops:



should i find a new adapter ??


:?:



Thnks,

Taavet M. :wink:
User avatar
Biopyro
Corporal 2
Corporal 2
Posts: 654
Joined: Fri Aug 04, 2006 5:32 am
Location: UK

It may be DWV (drain, waste, vent, not pressure rated). Check to see if you can find any sort of rating on it. Usually it's on the side of the walls and will be in PSI in the US of MPa in the UK. If it's a simple combustion you could risk it, but realistically it's much better just to replace it.
Those who would give up Essential Liberty to purchase a little Temporary Safety, deserve neither Liberty nor Safety. -Benjamin Franklin
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

You mean like this?
Image


Well that means it's probably thin-wall PVC, used on houses as guttering. It's thinner then DWV and I would not personally use it for that reason.

If you are building a combustion, try and use thicker PVC pipe and fittings, DWV should be fine but there is a chance it could explode. In that case you'll need to use pressure rated parts.

In a pneumatic or 'advanced combustion' (uses metered propane or MAPP) I would recommend to never, ever use DWV PVC. DWV isn't pressure rated, meaning it's never been pressure tested and you'll never know how low of a pressure it could blow up at.

Here's an article on how-to identify pressure rated PVC:
http://www.spudfiles.com/spud_wiki/inde ... _Rated_PVC
Taavet
Private
Private
Posts: 11
Joined: Thu Jun 05, 2008 2:46 pm

well... thnx guys for your fast response!


cheers!

i'll keep that in mind , when i go shop for more parts





Taavet. :wink:
User avatar
SpudFarm
First Sergeant 3
First Sergeant 3
Posts: 2571
Joined: Sat Nov 04, 2006 9:39 am
Location: Norway Trondheim area

we have those in Nowray. DWV

(my split in a spray and pray)
"Made in France"
- A spud gun insurance.
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

spudfarm wrote:we have those in Nowray. DWV

(my split in a spray and pray)
Everyone has them everywhere.

Like I said, the one in the picture is used on houses for guttering, it's not DWV but down-pipe or spouting. It's thinner then DWV and far more dangerous to use.
User avatar
SpudFarm
First Sergeant 3
First Sergeant 3
Posts: 2571
Joined: Sat Nov 04, 2006 9:39 am
Location: Norway Trondheim area

i did post my reply before you MC :)

(my fitting was not like that but simmilar) (simular?)
"Made in France"
- A spud gun insurance.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post
  • Valves, the difference opening time makes.
    by Zen/// » » in Pneumatic Cannons
    46 Replies
    13754 Views
    Last post by bigbob12345
  • Cup Shape Piston
    by jrrdw » » in General Cannon Discussion
    29 Replies
    7505 Views
    Last post by Willdebeers
  • Piston shape
    by daccel » » in General Cannon Discussion
    30 Replies
    7433 Views
    Last post by USGF
  • chamber shape
    by <WOG> » » in Combustion Cannons
    8 Replies
    2702 Views
    Last post by jimmy101
  • Most Efficient Projectile Shape
    by Floyd » » in Ammo & Materials
    101 Replies
    33902 Views
    Last post by saefroch