Hey, is there any way of making a sprinkler valve fully automatic? Or at least semi?If there is, could you point me in the right direction?
thanks
Automatic Sprinkler Valve?
Well yes I suppose but you may as well use a Q.E.V. If I'm bit mistaken a QEV and a popoff valve will make full auto but the pressurizing is the hard part. First off you need a constant air source for it. once you have that, and a clip you have semi auto. A clip could be a tube sticking up from the barrel. So worry about air source and loading first then buy the valve parts.
- jackssmirkingrevenge
- Five Star General

- Posts: 26219
- Joined: Thu Mar 15, 2007 11:28 pm
- Has thanked: 582 times
- Been thanked: 348 times
The problem with sprinkler valves is that they usually take long to reset after opening, so as suggested above you're better off with a QEV.
.. and QEV + pop-off valve = full auto
.. and QEV + pop-off valve = full auto
hectmarr wrote:You have to make many weapons, because this field is long and short life
With dont mod a sprinkler valve with a safety pop-off valve instead of a blowgun and wihle the gun is repressuring reload with a bolt action system?The problem with sprinkler valves is that they usually take long to reset after opening
Thanks guys
and Demon im not quite sure what you said, but I assume that you said I could hook up a pop-off with a sprinkler and it should work?
And also, assuming I have the same setup as the gun that JSR showed me , would I be able to substitute a "homemade QEV" (piston valve that they use on french forum, http://patator.frbb.net/) would it work or would it take to long to reset?
and Demon im not quite sure what you said, but I assume that you said I could hook up a pop-off with a sprinkler and it should work?
And also, assuming I have the same setup as the gun that JSR showed me , would I be able to substitute a "homemade QEV" (piston valve that they use on french forum, http://patator.frbb.net/) would it work or would it take to long to reset?
- MrCrowley
- Moderator

- Posts: 10078
- Joined: Fri Jun 23, 2006 10:42 pm
- Location: Auckland, New Zealand
- Been thanked: 3 times
Regardless of pilot valve, a sprinkler valve takes too long to reset. Seating time has little to do with the pilot valve. So no, it wouldn't be much different to a blowgun.Demon wrote:With dont mod a sprinkler valve with a safety pop-off valve instead of a blowgun and wihle the gun is repressuring reload with a bolt action system?The problem with sprinkler valves is that they usually take long to reset after opening