compressor check valve

Because potatoes only last one shot!
User avatar
roughboy
Specialist
Specialist
Posts: 197
Joined: Fri May 12, 2006 12:43 am

Do i really need to put a check valve, ball valve, pressure gauage on a fridge or air condition compressor?
Boys do what they can, Men do what they want
User avatar
jrrdw
Moderator
Moderator
United States of America
Posts: 6572
Joined: Wed Nov 16, 2005 5:11 pm
Location: Maryland
Has thanked: 39 times
Been thanked: 22 times
Contact:

It depends on where your talking about? In one area it will help build pressure, in another it will keep you from building to much.
User avatar
psycix
Sergeant Major 4
Sergeant Major 4
Posts: 3684
Joined: Mon Jun 25, 2007 7:12 am
Location: The Netherlands

Check valve: No.
Ball valve: You need a bleed valve to get the pressure of your line if you want to disconnect the quickdisconnect. On high pressures you cannot detach a QD, and even if you manage to, you are ruining the QD.
A ballvalve can do this job.
Pressure gauge: Highly advisable. You will need to know how much pressure it is putting out dont you?
Till the day I'm dieing, I'll keep them spuddies flying, 'cause I can!

Spudfiles steam group, join!
User avatar
roughboy
Specialist
Specialist
Posts: 197
Joined: Fri May 12, 2006 12:43 am

[img][img]http://img23.imageshack.us/img23/5512/73381710.png[/img]

Is this setup right or do i have to change something?
Boys do what they can, Men do what they want
User avatar
ramses
Staff Sergeant 2
Staff Sergeant 2
United States of America
Posts: 1679
Joined: Thu May 29, 2008 6:50 pm

no, this is better. I would use quick connects instead of schrader.
Attachments
better.JPG
better.JPG (25.63 KiB) Viewed 3860 times
POLAND_SPUD wrote:even if there was no link I'd know it's a bot because of female name :D
User avatar
roughboy
Specialist
Specialist
Posts: 197
Joined: Fri May 12, 2006 12:43 am

why quick connects instead a schrader valve?
Boys do what they can, Men do what they want
User avatar
ramses
Staff Sergeant 2
Staff Sergeant 2
United States of America
Posts: 1679
Joined: Thu May 29, 2008 6:50 pm

I have seen them used to higher pressures more often, so I conclude that they would be less likely to fail, especially if you use salvaged male schrader valves from tires or something.

also, make sure the hose is rated above you max operating pressure.
POLAND_SPUD wrote:even if there was no link I'd know it's a bot because of female name :D
User avatar
psycix
Sergeant Major 4
Sergeant Major 4
Posts: 3684
Joined: Mon Jun 25, 2007 7:12 am
Location: The Netherlands

You can use a shrader, but I had a lot of shrader chucks that leaked. Quick connects seal better and work fine on high pressures. You just need to bleed off pressure before disconnecting, thats all.

Ramses is right about the ballvalve placement.
Till the day I'm dieing, I'll keep them spuddies flying, 'cause I can!

Spudfiles steam group, join!
User avatar
Gippeto
First Sergeant 3
First Sergeant 3
Venezuela
Posts: 2504
Joined: Sat Jan 19, 2008 10:14 am
Location: Soon to be socialist shit hole.
Has thanked: 2 times
Been thanked: 17 times

If you want to use a schrader, I'll recommend getting one of these;

http://www.aircraftspruce.com/catalog/l ... seneck.php

It threads on to the schrader valve, and is rated to 3000psi.

For the record...a schrader valve that threads in, has been tested to 10 000psi, by me. It cut the seal, but did not otherwise fail.

At 4350psi, it didn't even cut the seal. (300bar)
"It could be that the purpose of your life is to serve as a warning to others" – unknown

Liberalism is a mental disorder, reality is it's cure.
User avatar
roughboy
Specialist
Specialist
Posts: 197
Joined: Fri May 12, 2006 12:43 am

Ramses's design is good i know but i want to change the design so is this good or should i change something?

Image

Last edited by roughboy on Sat Apr 25, 2009 10:01 pm, edited 1 time in total.
Boys do what they can, Men do what they want
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

@roughboy
so does it work with a starting relay ??


this design is better as there are two 'out going' ports - one for a bleed valve/ball valve and one for the air hose...

once you have time to improve your setup you can add one more T to get one more port for an air tank ( it's a really useful addition - just make sure it is rated high enough)


I know that psycix told you that before but it's worth stressing -> use quick connect fitings... it's easier to get a good QC fittings than shraders... and it makes life easier in the long run

there are QC fittings that are specifically designed to work with higher pressures - but you can use normal ones
Children are the future

unless we stop them now
User avatar
inonickname
First Sergeant 4
First Sergeant 4
Posts: 2606
Joined: Sun Dec 07, 2008 3:27 am

I repeatably use schraders to 300-400 psi routinely, but they are clean, unused and brand new. Air chucks are rubbish, so if you're using schraders you need a screw on connection such as in shock pumps. Quick disconnects are the best in my opinion.
PimpAssasinG wrote:no im strong but you are a fat gay mother sucker that gets raped by black man for fun
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post