blow gun help

Cannons powered by pneumatic pressure (compressed gas) using a valve or other release.
Atrocity
Private
Private
Posts: 12
Joined: Thu Mar 26, 2009 2:44 pm

I recently modified my sprinkler valve and i can only get to 60 psi because all of my blow guns leak in the same area. I have a ch one and that one leaked, so i thought it was broken, so then i went to go buy a husky one and that one leaks in the same area to. Is this a common problem and what can i do to fix this?
User avatar
ramses
Staff Sergeant 2
Staff Sergeant 2
United States of America
Posts: 1679
Joined: Thu May 29, 2008 6:50 pm

Did you use Teflon tape? That's important. Also, make sure you thread the 1/4" npt end into the sprinkler valve. To clarify, the input goes to the sprinkler valve. If you connect it the other way, air will push the valve open and it will leak.
POLAND_SPUD wrote:even if there was no link I'd know it's a bot because of female name :D
User avatar
c11man
Corporal 3
Corporal 3
Posts: 783
Joined: Fri Feb 06, 2009 4:37 pm
Location: Wisconsin, USA

do you the blow gun on backwards?

EDIT: damn like 30 seconds too late...
Atrocity
Private
Private
Posts: 12
Joined: Thu Mar 26, 2009 2:44 pm

its leaking where i circled in red. I think i have it the right way, the 1/8 port is where i have it screwed it(circled blue)

Image
User avatar
c11man
Corporal 3
Corporal 3
Posts: 783
Joined: Fri Feb 06, 2009 4:37 pm
Location: Wisconsin, USA

you are putting the air in on the wrong side...

switch it and it will be fine.

when you put air into the output side it is very common for the air to leak around the area in red in your pic
Atrocity
Private
Private
Posts: 12
Joined: Thu Mar 26, 2009 2:44 pm

c11man wrote:you are putting the air in on the wrong side...

switch it and it will be fine.

when you put air into the output side it is very common for the air to leak around the area in red in your pic
lol rookie mistake

thanks got it working fine
User avatar
c11man
Corporal 3
Corporal 3
Posts: 783
Joined: Fri Feb 06, 2009 4:37 pm
Location: Wisconsin, USA

i realy like this leaking because i have a small little plinker and i use a blowgun as a main vavle and i have very tight ammo that seals. when i breach load the ammo the excess air leakes out through that hole making loading a TON easier.

BTW did you mod the blow gun? if not i would suggest it because it will have MUCH greater flow and will acuate the sprinkler valve slighty better.

EDIT: modding a blow gun is a great way to waste 30 minutes on a rainy day
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post