Not better tools, just PVC glue and primer instead of (more expensive!) epoxy. :wink:
User avatar
saefroch
Staff Sergeant 2
Staff Sergeant 2
Posts: 1679
Joined: Mon Jun 08, 2009 8:47 am
Location: U.S.A.- See Map

Apologies. I now see you suggested that the screws were the source of the leaks.

Unless you're using a PVC glue type I'm not familiar with, you're solvent-welding the PVC. This results in an area that is thicker and stronger than the rest of the pipe.
warhead052
Staff Sergeant 3
Staff Sergeant 3
Posts: 1769
Joined: Mon Mar 21, 2011 5:41 pm

No problem sae. Mark, I really do need better tools, or at least a corded drill...
User avatar
Crna Legija
First Sergeant 2
First Sergeant 2
Posts: 2333
Joined: Sun Jul 20, 2008 5:14 am
Location: australia

id save up and get a really good cordless drill. i have a Dewalt DC988KC-XE, its a beast comes with 3 batterys each one lasts a day most of the time. full charges in about 2hr and its got plenty off power. also come with a the heavy duty steel chuck. its $500 aus but its defiantly worth it.
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson

Add me on ps3: wannafuk, 8/11/11 cant wait
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

I have your basic 3/8" keyed-chuck corded drill. Plenty of torque for drilling through steel pipe and you don't have to worry as much about your bit slipping around in the chuck as you do with cheaper keyless chucks like you find on some cordless drills.
warhead052
Staff Sergeant 3
Staff Sergeant 3
Posts: 1769
Joined: Mon Mar 21, 2011 5:41 pm

I need a corded with alot of torque and ajustable speed, or a drill press. Plus I need a air compressor rather than a bike pump...
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

If you've got a good choice between the corded drill and the drill press... get both. :P Both have their many uses.
warhead052
Staff Sergeant 3
Staff Sergeant 3
Posts: 1769
Joined: Mon Mar 21, 2011 5:41 pm

Too true. My grandfather has a drill press I could use, but I am not sure if he would let me.... EDIT, I discarded the tanks (it was old pvc anyways...) and I rebuilt another... The cement has dried and has no leaks what so ever, and I applyed epoxy over it because I felt double reinforcement was better than 1 layer.
User avatar
Gun Freak
Lieutenant 5
Lieutenant 5
Posts: 4971
Joined: Mon Jan 25, 2010 4:38 pm
Location: Florida
Been thanked: 8 times

Doesn't sound like you gave it much cure time :?
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna"M16 BBMGPengunHammer Valve Airsoft SniperHigh Pressure .22 Coax
Holy Shat!
User avatar
clemsonguy1125
Sergeant 5
Sergeant 5
Posts: 1485
Joined: Tue Jul 21, 2009 4:00 pm
Location: East Coast

My glue take 2 hrs to cure according to the can.
User avatar
Gun Freak
Lieutenant 5
Lieutenant 5
Posts: 4971
Joined: Mon Jan 25, 2010 4:38 pm
Location: Florida
Been thanked: 8 times

Same here but I always give it at least a day...
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna"M16 BBMGPengunHammer Valve Airsoft SniperHigh Pressure .22 Coax
Holy Shat!
User avatar
clemsonguy1125
Sergeant 5
Sergeant 5
Posts: 1485
Joined: Tue Jul 21, 2009 4:00 pm
Location: East Coast

I give it two hours before 30 psi, then 1 day before any more.
warhead052
Staff Sergeant 3
Staff Sergeant 3
Posts: 1769
Joined: Mon Mar 21, 2011 5:41 pm

Mine is 1 hour... Really good glue too, :D. I usually put it to 20 psi for now, and after a day or two send it up to past 50.
warhead052
Staff Sergeant 3
Staff Sergeant 3
Posts: 1769
Joined: Mon Mar 21, 2011 5:41 pm

Well, I figured I would let you guys know... I got a almost brand new empty freeon tank! Very heavy duty... My dad ran by an old friend who owns a auto shop juts around the corner and asking if he had any thing and he said that he had no use for the tank and it was too heavy to recycle (dont see how when they simply melt it down...). High pressure tank, about 300 - 600 psi or something close to that. It came off a freeon recovery unit for a car, which means it pulled the freeon that was charged up. Its built to last and hold pressure! No need for my crappy pvc air tank anymore... :P
User avatar
Technician1002
Captain
Captain
Posts: 5189
Joined: Sat Apr 04, 2009 11:10 am

Just a quick note on the Freon Recovery tanks. Because they are refillable as opposed to the disposable tanks, they are much heavier.

If you intend to do any welding on it, you will find it has lots of oil residue. Watch for build up of explosive oil fumes if welding. Either fill the tank with water first or run a constant inert gas in the tank to keep Oxygen out. Argon, Nitrogen, or CO2 work for the purge gas. Don't use compressed air.

The tank may have been disposed of due to the 3 year recertification required. Check the manufacture date. Is it older than 3 years? If it is older than 3 years, does it have a newer date stamped in the metal near the valve? Is that date older than 3 years?

If the tank is expired, don't plan on exceeding 300 PSI with it. If you weld on it, limit is 1/2ed.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post