Anyone want to sell a 2inch sprinkler valve

Because potatoes only last one shot!
User avatar
Lockednloaded
Staff Sergeant
Staff Sergeant
United States of America
Posts: 1566
Joined: Thu Sep 03, 2009 9:38 pm
Location: Texas, USA
Been thanked: 7 times

Well solenoid piloted valves should perform in the same manner as a QEV, but the one Matty posted is a direct acting valve, and cannot be modifyed
I love lamp
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

So a 3/4 inch QEV performs as good as a 2inch solenoid valve?
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

What? No way, what gave you that idea?
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

I don't know. All the comments are confusing me.
User avatar
mattyzip77
Sergeant 3
Sergeant 3
United States of America
Posts: 1249
Joined: Tue Jun 28, 2011 12:22 pm
Location: Taxachusetts

Bigger valve equals more air flow equals moar power!!
@ L&L no need to modify, its pretty much plug and play.
Go Bruins!!!!
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

This thread has been pretty much about QEV's so I thought I would kind of change it and say. Is there someone who has a 2inch valve who is willing to sell it for a reasonable price?
User avatar
Technician1002
Captain
Captain
Posts: 5189
Joined: Sat Apr 04, 2009 11:10 am

From the link...
125PSI (850kPa) Max, 1 3/4" Orifice
Edit. It is a 1-1/2 inch valve. Found the PDF. http://www.industrialzone.com/rca45dd000.html
Flow CV is listed as 51.

mattyzip77 wrote:
8tonsemi wrote:So to modify you just unscrew the plug on the top. No drilling involved. And thanks for all the help :lol http://www.ebay.com/itm/GOYEN-CONTROLS- ... 876wt_1205

also how bout this it has 3inch ports.
It says it has 3 inch ports but they are definatly not. I seen this one too and my eyes lit up when I saw 3 inch. They are either 1 or 1 1/2 inch. Also I dont know how good this one would be under pressure due to those ports.

@wyz2285 I said basically the same thing, not the same thing.

@jsefcifk no, its not that easy.
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

Is this type of sprinkler valve modifyable. I'm going to pilot it with a 1inch orbitz valve.
http://www.ebay.com/itm/Irritrol-2-elec ... _500wt_115
User avatar
dewey-1
Sergeant 3
Sergeant 3
Posts: 1298
Joined: Wed Mar 28, 2007 10:24 am
Location: NE Wisconsin USA

User avatar
mattyzip77
Sergeant 3
Sergeant 3
United States of America
Posts: 1249
Joined: Tue Jun 28, 2011 12:22 pm
Location: Taxachusetts

For the 100th time, try to make a offer on this valve. Then you dont have to mod it it or pilot it with another valve.


http://www.ebay.com/itm/Goyen-Diaphragm ... 1-1-2-NPT- Aluminum-125-PSI-Max-NEW-/251005160243?pt=LH_DefaultDomain_0&hash=item 3a7112cb33#ht_500wt_936

Actually, I bid 30 dollars on the thing, never thinking the guy would go for it and he accepted the offer. I DO NOT want the thing, if you do, I will message him and tell him to give it to you. Let me know asap!!
Go Bruins!!!!
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

I'm looking for a 2inch sprinkler valve again so if you have one let me know. If we can agree on a fair price I'll buy it.
User avatar
mattyzip77
Sergeant 3
Sergeant 3
United States of America
Posts: 1249
Joined: Tue Jun 28, 2011 12:22 pm
Location: Taxachusetts

Be patient with e bay. One will pop up eventually. The 2 inch valve is def better for soda cans but I think you should at least try a 2 1/2 inch barrel on your dust collector. Keep in mind you can go well over 200 psi with it where with a sprinkler valve you cant go anywhere near that because its only pvc. Also a 3/4 qev would be the way to go to pilot the big sprinkler valve not a 1/4 inch qev. I think evan made a typo!!
Go Bruins!!!!
User avatar
8tonsemi
Specialist 3
Specialist 3
Posts: 321
Joined: Thu Feb 16, 2012 6:08 pm
Location: The moon

My cement is only rated to 180 so I cant go that high.
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

Yeah, I wouldn't take 2" PVC over 150PSI even if it's rated for 260PSI without hydrostatic testing it.
User avatar
mattyzip77
Sergeant 3
Sergeant 3
United States of America
Posts: 1249
Joined: Tue Jun 28, 2011 12:22 pm
Location: Taxachusetts

I keep forgetting My cannon is schedule 80. In all the pressure tests I have seen the pipe always breaks not anywhere near the fittings or around them.
Go Bruins!!!!
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post