When useing a pneumatic cannon, How much expantion is caused by the pressure?
Does this expantion cause slop in the piston?
Does anybody allow tolerances for this?
Maby Joel does, maby thats the differance between the supra and everybody elses!!!
Expanding Pipe
-
screamingflea
- Private 2

- Posts: 33
- Joined: Wed Mar 29, 2006 4:12 pm
I'm betting very little expansion happens, or else everybody's pistons would leak. Enless they had super thick O-rings, but then they wouldn't be able to get the piston in the gun in the first place.
- boilingleadbath
- Staff Sergeant 2

- Posts: 1635
- Joined: Sat Mar 12, 2005 10:35 pm
- Location: Pennsylvania, USA
Well, ok, here's my attept at figuring out how much the pipe will stretch...
For 4" sch 40 PVC pipe (3.998" ID, .237" wall)...
Ok, so at 100 psi there is a hoop stress of about 100psi*3.998"*1/2pi = 2650 psi.
This means that the pipe will enlongate 1 part in 420,000psi/2650psi = 1/159.
1 part in 159 times 3.998" mean the ID of the pipe will enlarge .025".
With a typical 3/16" thick O-ring (which is really the smallest I'd put on such a big piston), this means that the compression of the O-ring will be reduced ~7.5%.
O-rings in gas systems are typicaly compressed 5-10%.
For 4" sch 40 PVC pipe (3.998" ID, .237" wall)...
Ok, so at 100 psi there is a hoop stress of about 100psi*3.998"*1/2pi = 2650 psi.
This means that the pipe will enlongate 1 part in 420,000psi/2650psi = 1/159.
1 part in 159 times 3.998" mean the ID of the pipe will enlarge .025".
With a typical 3/16" thick O-ring (which is really the smallest I'd put on such a big piston), this means that the compression of the O-ring will be reduced ~7.5%.
O-rings in gas systems are typicaly compressed 5-10%.
boilingleadbath wrote:Well, ok, here's my attept at figuring out how much the pipe will stretch...
For 4" sch 40 PVC pipe (3.998" ID, .237" wall)...
Ok, so at 100 psi there is a hoop stress of about 100psi*3.998"*1/2pi = 2650 psi.
This means that the pipe will enlongate 1 part in 420,000psi/2650psi = 1/159.
1 part in 159 times 3.998" mean the ID of the pipe will enlarge .025".
With a typical 3/16" thick O-ring (which is really the smallest I'd put on such a big piston), this means that the compression of the O-ring will be reduced ~7.5%.
O-rings in gas systems are typicaly compressed 5-10%.
Daaaammmm
- rna_duelers
- Staff Sergeant 3

- Posts: 1739
- Joined: Mon Sep 26, 2005 7:07 am
- Location: G-land Australia
did some one say education???BLB stop making the rest of us look dumb!lol
Create an account or sign in to join the discussion
You need to be a member in order to post a reply
Create an account
Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute
Sign in
-
- Similar Topics
- Replies
- Views
- Last post
-
- 30 Replies
- 8484 Views
-
Last post by SpudFarm
-
- 3 Replies
- 1467 Views
-
Last post by spudshot
-
- 8 Replies
- 7383 Views
-
Last post by Devilsmed98
-
- 6 Replies
- 3888 Views
-
Last post by psycix
-
- 11 Replies
- 5862 Views
-
Last post by Benny