Helps on 2" porting piston valve

Cannons powered by pneumatic pressure (compressed gas) using a valve or other release.
jmeyer1022
Specialist 2
Specialist 2
Posts: 200
Joined: Sun Nov 09, 2008 4:50 pm

So far I've been trying to come up with a 2" tee with 2" porting without using an adapter on the outlet side, but so far that's the only way I can think of.
It's simply 2" sch 80 pipe into the lip of the tee, then 1 1/2 pipe sleeved/glued into that until the middle of of the tee. then with a little bit of the sch 80 sticking out a 2" adapter glued onto that.
Diagram:
Black= 2" tee
Red= Sch 80 2" pipe
Blue: 1 1/2" pipe sleeved/glued into sch 80
Light Blue: Slipx FIPT 2" adapter

Image

This seems like a good idea, but I want to try an house it all in a tee, I'll probably have to move up to a 2.5" tee.
User avatar
jrrdw
Moderator
Moderator
United States of America
Posts: 6572
Joined: Wed Nov 16, 2005 5:11 pm
Location: Maryland
Has thanked: 39 times
Been thanked: 22 times
Contact:

I'm affaid I don't understand your question.
User avatar
Carlman
Staff Sergeant 2
Staff Sergeant 2
Posts: 1618
Joined: Sat Nov 24, 2007 1:18 am
Location: Western Australia
Been thanked: 2 times

If you do that mate youve got 1.5" porting still just with 2" threads
Image
Aussie spudders unite!!
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

As carlman said, that only gives you 2" threads, not a 2" (nominal diameter) port that the piston valve seals against...which can't be done in a 2" tee.

What you've done is similar to what I did here:
http://www.spudfiles.com/forums/viewtop ... tml#186844
jmeyer1022
Specialist 2
Specialist 2
Posts: 200
Joined: Sun Nov 09, 2008 4:50 pm

Ok, We'll looking for 2" threads, prefer port to be around 1.5", is there a way I can go about doing this while keeping it in the tee.
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

There's really no practical way other than somehow getting it all to work in a threaded tee. If you were to get a larger tee, then there's really no reason not to use larger porting as well...

I say use a modified version of your original plan and don't worry about the little extra length. Simply use two 2" x 1-1/2" bushings in place of the 2" SCH-80, and then modify the back on so that 1-1/2" pipe slides through it.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post