Question on a new way of modding a sprinkler vavle

Cannons powered by pneumatic pressure (compressed gas) using a valve or other release.
User avatar
glass_05
Private 4
Private 4
Posts: 74
Joined: Sun Apr 27, 2008 7:08 pm
Location: Iowa
Contact:

i have modded many sprinkler valves before, but my question is if its possible to fill the chamber by using the same modded sprinkler valve part. let me explain

can you use sprinkler valve like this:
Image

and then put a tee on it instead of just the barb. that way you can fill it up and trigger it from the sprinkler valve. here is a similar setup, but i know this isnt with a rainbird
Image

want i basically want to do is be able to use the sprinkler valve mod to fill and trigger the gun.
User avatar
Technician1002
Captain
Captain
Posts: 5189
Joined: Sat Apr 04, 2009 11:10 am

It can be done. The EQ port in the diaphragm is small so the fill time will take a while. The hazard with filling with the pilot side is the accidental discharge when you disconnect the air hose. For these reasons, this is why filling from the pilot is not recommended.
UKSGC
Private 3
Private 3
Posts: 42
Joined: Sun Jan 21, 2007 5:17 pm
Location: Cornwall UK
Contact:

You could use a check valve and eliminate the chance of an accidental launch on hose removal.
User avatar
Technician1002
Captain
Captain
Posts: 5189
Joined: Sat Apr 04, 2009 11:10 am

UKSGC wrote:You could use a check valve and eliminate the chance of an accidental launch on hose removal.
True, for additonal $.. and that fixes just one of the problems.
User avatar
inonickname
First Sergeant 4
First Sergeant 4
Posts: 2606
Joined: Sun Dec 07, 2008 3:27 am

The fill rate will be slower, but this will eliminate the problem of fill honking. If you've ever filled a sprinkler valve very fast the pressure overcomes the spring and opens the valve, make it honk and waste air.
PimpAssasinG wrote:no im strong but you are a fat gay mother sucker that gets raped by black man for fun
MRR
Specialist 3
Specialist 3
Posts: 361
Joined: Tue Feb 17, 2009 2:29 pm

Look at the 2nd picture. With that setup there shouldn't be a problem with accidental firing.

At least if you always remember to close the ball valve before disconnecting the fill hose.

There was a post a while ago with the idea of bypassing the air input...
fill valve -> sprinkler -> check valve -> hose -> chamber
...for a faster refill without honking.

Sounds quite good to me but I don't know if its feasible.
User avatar
Hubb
First Sergeant 2
First Sergeant 2
Posts: 2390
Joined: Mon May 28, 2007 8:39 am
Location: South Georgia
Contact:

I modify most of my sprinkler valves to fill from the pilot side. It actually seems to perform better doing it that way to me.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post