Do I want to drill and tap through just the PVC tube, or go through the tube, and a fitting aswell?
User avatar
Spyider
Specialist
Specialist
Posts: 122
Joined: Thu Jul 06, 2006 11:18 pm
Location: Wisconsin
Contact:

when i have to screw stuff into my pipes i just drill a hole that is a little smaller than what im inserting then i just screw it into it and it makes its own threds then i take it out and out some "tape" on it then reinsert it. and that usually sealls it tight but if i rly need more i just put some apoxey.
User avatar
Kris.Is.Awesome
Private 4
Private 4
Posts: 72
Joined: Tue Jul 11, 2006 2:52 pm
Location: Virginia Beach, VA
Contact:

I know how to drill and tap, I just need to know if I should put it through a fitting- maybe it's stronger.

Can I mount it like this? Is that fitting strong enough to mount it on the 'slant'? Or should I mount it on the flat part- or maybe just the tube?


Image




It's one of theese fittings- I wanna put it on the slant.

Image
Last edited by Kris.Is.Awesome on Mon Jul 31, 2006 3:14 pm, edited 1 time in total.
User avatar
LucyInTheSky
Specialist 2
Specialist 2
Posts: 293
Joined: Fri Apr 21, 2006 11:46 am

Mount it so it goes through two layer of PVC where the fitting and Pipe overlap.
User avatar
Kris.Is.Awesome
Private 4
Private 4
Posts: 72
Joined: Tue Jul 11, 2006 2:52 pm
Location: Virginia Beach, VA
Contact:

LucyInTheSky wrote:Mount it so it goes through two layer of PVC where the fitting and Pipe overlap.

Okay- thanks. Will do.
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

That looks like a DWV reducing coupling. Not safe for a pneumatic at all...
User avatar
Kris.Is.Awesome
Private 4
Private 4
Posts: 72
Joined: Tue Jul 11, 2006 2:52 pm
Location: Virginia Beach, VA
Contact:

markfh11q wrote:That looks like a DWV reducing coupling. Not safe for a pneumatic at all...

That picture was to illustrate the general coupling I used- Are you saying it's a bad Idea?
User avatar
Shrimphead
Corporal
Corporal
Posts: 509
Joined: Thu Nov 17, 2005 7:42 pm

Check to see if the fitting says "NSF-pw" on it. If it doesn't than it means that it's not a pressure rated fitting.
Controlled insanity = Genius
Life flies when you're being dumb.
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3643
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 62 times
Contact:

Look also for ASTM 2466.
iamquaker
Private
Private
Posts: 3
Joined: Sat Aug 05, 2006 11:43 pm

so it would not be wise to just tap a hole in the 2" pvc and screw in a pressure gauge if its only going thru one layer of pvc?

would this weaken the pvc and make it rupture where you drilled it?
User avatar
CS
Moderator
Moderator
Posts: 1837
Joined: Fri Feb 18, 2005 5:32 pm
Location: Southern Utah

Mer... The whole reason why it is recommended that you tap threw two layers of PVC is so that the component being "tapped" into there has more material to "grip" on.

Im not completly sure on this, but if I recall correctly reducing/increasing couplings are a thing of the "non-pressure rated" realm, regardless of manufactuer. Ive used them in pneumatics up to 125PSI (thats as high as my compressor goes). I wouldnt scrap your whole gun over such a fitting, but for futures safety Id recommend pressure rated bushings in future builds.
pyrogeek
Specialist 4
Specialist 4
Posts: 457
Joined: Sat May 13, 2006 7:43 pm
Location: moline Illinios

Going through 2 layers would be best. And I don't care what other people say, use a drill and tap to cut your threads. You can buy taps seperately, and they are only like $3 or $4 each, so they aren't that expensive. And if it's something like a 1/4 NPT tap, it will get plenty of use to justify that expense.

And by the way, ball valves don't have that good of performance. Sprinkler vavles > ball valves.
User avatar
LucyInTheSky
Specialist 2
Specialist 2
Posts: 293
Joined: Fri Apr 21, 2006 11:46 am

and QEV > sprinkler valves
User avatar
Flying_Salt
Corporal 3
Corporal 3
Posts: 779
Joined: Mon Oct 09, 2006 4:57 pm
Location: Texas

And just to be safe if you wanna, do what I do and put a bit of caulk on there. it helps seal it off.
User avatar
jon2680
Private 2
Private 2
Posts: 39
Joined: Tue Oct 31, 2006 5:58 pm
Location: Alberta Canada

you could also use a snap tee.
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post