Well there's your problem.
It only needs maybe 1 1/2 inches, perhaps less.
The piston had a large runup, but it had to stop in rather a small amount of space, there's a lot of force in a piston at full speed, couple that with PVC that's brittle, even more so in low temperatures, and not much of a bumper.
I wonder if the piston could launch itself out of the piston housing into the firer?
the reason why you want a good bumper in a piston valve
-
hollowpoint666
- Private

- Posts: 5
- Joined: Wed Jul 14, 2010 2:14 pm
by firer do you mean operator/ the person using the cannon? then yes, the piston flew out the back and hit my house leaving a large gash in the siding, if it wasnt for the size of the cannon, requiring me to hold it from the side (it is / was 9' long) it would have hit me for sure, i was lucky it didnt smash into my hand that turned the valveZeus wrote:Well there's your problem.
It only needs maybe 1 1/2 inches, perhaps less.
The piston had a large runup, but it had to stop in rather a small amount of space, there's a lot of force in a piston at full speed, couple that with PVC that's brittle, even more so in low temperatures, and not much of a bumper.
I wonder if the piston could launch itself out of the piston housing into the firer?
- Crna Legija
- First Sergeant 2

- Posts: 2333
- Joined: Sun Jul 20, 2008 5:14 am
- Location: australia
yea that way to much travel you only need 1/4 the dia of your barrel port.
and that hole cannon looks like its made from dwv, not surprising it blow up.
and that hole cannon looks like its made from dwv, not surprising it blow up.
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
- mark.f
- Sergeant Major 4


- Posts: 3643
- Joined: Sat May 06, 2006 11:18 am
- Location: The Big Steezy
- Has thanked: 58 times
- Been thanked: 62 times
- Contact:
Fittings do not have a specific pressure rating stamped on them. They have the NSF and ASTM ratings. You are correct that the NSF ratings are for the type of service (drainage/waste/etc. or potable water), which more often than not corresponds with a pressure rating since potable water is delivered at pressure nearly everywhere in the continental United States. There are more NSF ratings as well.Ragnarok wrote:The rating is the number that says 240 psi (or whatever other pressure), never the NSF mark.
However, the final status on pressure rated vs. non pressure rated should be taken from the ASTM marking. For solid core pressure rated SCH-40 PVC fittings, the rating is ASTM D2466.
Create an account or sign in to join the discussion
You need to be a member in order to post a reply
Create an account
Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute
Sign in
-
- Similar Topics
- Replies
- Views
- Last post
-
- 27 Replies
- 4927 Views
-
Last post by dongfang
-
- 18 Replies
- 5491 Views
-
Last post by A-98
-
- 11 Replies
- 4831 Views
-
Last post by Hayseed_Andrew
-
- 8 Replies
- 2433 Views
-
Last post by mark.f
-
- 1 Replies
- 721 Views
-
Last post by spudthug