Cannons powered by pneumatic pressure (compressed gas) using a valve or other release.
User avatar
iPaintball
Corporal 2
Corporal 2
Posts: 695
Joined: Sun Mar 04, 2007 8:37 pm

Is it okay to use dwv reducers for my cannon? I can't find any 3" bushings so I have to take my 3" chamber down to a 2" port to glue in a bushing. I've seen a couple other people do it (Scott's Cannon) and I can't order anything of of mcmaster. Thanks for any help!
User avatar
hi
Staff Sergeant 2
Staff Sergeant 2
Posts: 1619
Joined: Thu Feb 01, 2007 9:28 pm

if its combustion its ok. pneumatic, probably not to smart.
User avatar
Velocity
Sergeant
Sergeant
Posts: 1039
Joined: Tue Feb 07, 2006 5:42 pm

I do not take any shortcuts, even on my combustion (which is currently in the works). Anything 0-80 PSI is SCH 40; 80 PSI any beyond is SCH 80 or some type of metal. Some people are much more willing to take risks; I have seen DWV pneumatics being taken to 120 PSI, and SCH 40 being taken to over 200 PSI.

If you are a great solvent welder, then DWV would probably be OK for a low pressure pneumatic. If you want to feel safe all the time however, spend the extra dollars and get the pressure rated parts.
User avatar
iPaintball
Corporal 2
Corporal 2
Posts: 695
Joined: Sun Mar 04, 2007 8:37 pm

It's a pneumatic, and I am a really good solvent welder. The reducer is SCH 40, BTW...
User avatar
integral
Specialist 2
Specialist 2
Posts: 204
Joined: Fri Mar 09, 2007 11:54 pm
Location: Aussieland

dude... just spend some extra bucks and buy some nsfpw fittings. if ur trying to save some bucks.. just ask urself: is my eye worth 4 bucks?
User avatar
iPaintball
Corporal 2
Corporal 2
Posts: 695
Joined: Sun Mar 04, 2007 8:37 pm

Where can I buy pressure rated reducers?!! (I can't order them)
User avatar
hi
Staff Sergeant 2
Staff Sergeant 2
Posts: 1619
Joined: Thu Feb 01, 2007 9:28 pm

there has to be some place near you that has them. like integral said, is not worth it. you could use iron parts. they are only $7-10 or so and will hold way more than any pvc will ever hold.
User avatar
pyromaniac
Corporal 4
Corporal 4
Posts: 805
Joined: Tue Feb 27, 2007 7:18 pm
Location: MO

just wondering if you were as stupid as me and found the right reducer but thought it didn't work because it was the same size as your chamber.

If so buy a coupling and put it in there.
:pottytrain3:
User avatar
integral
Specialist 2
Specialist 2
Posts: 204
Joined: Fri Mar 09, 2007 11:54 pm
Location: Aussieland

if u cant find a reducer... just buy the other fittings such as bushings and couplings to make the nessecary fitting. if u weld it correctly... it would be just as strong.
User avatar
Pete Zaria
Corporal 5
Corporal 5
Posts: 954
Joined: Fri Mar 31, 2006 6:04 pm
Location: Near Seattle, WA

Actually, coupler and bushing is the most accepted way to change pipe size in pressure applications.

A coupler and bushing, both NSF-PW sch40, are what you're looking for. Open your phone book and call plumbing supply stores and sprinkler shops.

Peace,
Pete Zaria.
User avatar
iPaintball
Corporal 2
Corporal 2
Posts: 695
Joined: Sun Mar 04, 2007 8:37 pm

Thanks guys!
Post Reply

Create an account or sign in to join the discussion

You need to be a member in order to post a reply

Create an account

Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute

Register

Sign in

  • Similar Topics
    Replies
    Views
    Last post