Remember to mark some measuring points on the circuference of the tank, and take pre and post hydro measurements to compare. This way you'll be able to tell if the tank has hit yield (permanent deformation).
If you don't already know...hydrotest should last 3hrs minimum.
Have you run the tubing through Barlows?
1/2 inch bore metal cannon build
- Gippeto
- First Sergeant 3


- Posts: 2504
- Joined: Sat Jan 19, 2008 10:14 am
- Location: Soon to be socialist shit hole.
- Has thanked: 2 times
- Been thanked: 17 times
"It could be that the purpose of your life is to serve as a warning to others" – unknown
Liberalism is a mental disorder, reality is it's cure.
Liberalism is a mental disorder, reality is it's cure.
I am more concerned about the welds than anything else. I used to be a welder for a living, though. So, I know how to weld properly. However, That is the failure point, I would expect.
I did not know the test was 3 hours. That is no problem, though. I can leave it pressurized that long.
Matt
I did not know the test was 3 hours. That is no problem, though. I can leave it pressurized that long.
Matt
Exotic E-bike builder, air cannon builder, and overall crack-pot. ;~)
I just got an email from Granzow (the valve manufacturer I get a discount from). I may try out a new style valve they have. It is a fast acting diaphram valve good up to 1,000 psi with a CV (they list it as KV, liters per second) of 110. Not sure how that compares to CV.
Anyway, using a scuba or large paintball tank to pressurize the primary chamber up to 1,000 psi would make this thing a freakin BEAST!
I just may have to try it.
Matt
Anyway, using a scuba or large paintball tank to pressurize the primary chamber up to 1,000 psi would make this thing a freakin BEAST!
I just may have to try it.
Matt
Exotic E-bike builder, air cannon builder, and overall crack-pot. ;~)
- velocity3x
- Corporal 4

- Posts: 828
- Joined: Fri Jun 05, 2009 3:09 pm
- Location: Yuma, Arizona
- Contact:
Kv=Cubic meters per hour.High-PSI wrote:It is a fast acting diaphram valve good up to 1,000 psi with a CV (they list it as KV, liters per second) of 110. Not sure how that compares to CV.
A flow of 110 liters per second would equal a Cv of 1,743.
A Cv of 110 equals a flow of about 6.9 liters per second.
A Kv of 110 equals a Cv of 483
But....I could be totally wrong.
_________________
A government big enough to give you everything you want is big enough to take everything you have.
- velocity3x
- Corporal 4

- Posts: 828
- Joined: Fri Jun 05, 2009 3:09 pm
- Location: Yuma, Arizona
- Contact:
Thanks Dewey
Like I said, I could be wrong.... (as I often am)!
No problem.
You may have been mislead by liters per second.
KV is cubic meters per hour.
My guess is that it is a 3 inch NPT valve with high pressure rating.
You may have been mislead by liters per second.
KV is cubic meters per hour.
My guess is that it is a 3 inch NPT valve with high pressure rating.
Create an account or sign in to join the discussion
You need to be a member in order to post a reply
Create an account
Not a member? register to join our community
Members can start their own topics & subscribe to topics
It’s free and only takes a minute
Sign in
-
- Similar Topics
- Replies
- Views
- Last post
-
- 4 Replies
- 1007 Views
-
Last post by High-PSI
-
- 27 Replies
- 9350 Views
-
Last post by Technician1002
-
- 8 Replies
- 4219 Views
-
Last post by jackssmirkingrevenge
-
- 0 Replies
- 51712 Views
-
Last post by jackssmirkingrevenge
-
- 55 Replies
- 19228 Views
-
Last post by Technician1002


